We install pressurized water lines, gravity sewer laterals, and municipal mains using horizontal directional drilling (HDD) to avoid large open trenches, shorten restoration, and protect roads, drives, and landscaping. From residential service replacements to city infrastructure, our crews deliver clean, code-compliant bores with documented as-builts and photos.

Clean, Code-Compliant Water & Sewer Boring

HDD is ideal for water service replacements, new subdivision water loops, sewer laterals, and force mains because it protects surfaces and limits public disruption. We coordinate 811 locates, verify depths with potholing/daylighting, and hold proper separations from gas, electric, telecom, and other utilities. Our restoration-first approach reduces costs and keeps neighbors—and inspectors—happy.

For municipalities and utility contractors, we provide pilot bore steering, reaming plans, and pullback sequences sized to your pipe specs, along with bore logs and photo documentation. For homeowners, we offer straightforward service replacements and sewer line bores under drives and trees without tearing up the yard.

Residential Water & Sewer Bores

Replace failing water services, add new lines for shops or ADUs, or bore a sewer lateral under the driveway without trenching across your property. We protect landscaping, irrigation, and hardscapes while installing code-compliant depths and separations.

  • Water service replacements: copper, PVC, or HDPE
  • Sewer laterals under drives, sidewalks, and trees
  • Clean reinstatement; minimal yard impact
  • Coordination with your plumber on tie-ins and tests
Directional boring for residential water and sewer lines in Oklahoma
Municipal water and sewer HDD crossing in Oklahoma

Municipal & Developer Infrastructure

For cities and developers, we execute mains, loops, and crossings beneath roads, creeks, and utilities with engineered ream sequences, proper fluid programs, and as-built documentation. We coordinate permits, inspections, and traffic control as required.

  • Water mains (PVC/DI/HDPE) and sewer force mains
  • Carrier pipe in casing where specified
  • Critical depth control and code separations
  • Inspector coordination; photos and bore logs

Pipe, Materials & Installation Specs

We size pilot, ream passes, and pullback for your pipe material and diameter with the correct radii and entry/exit geometry.

ApplicationPipe/ConduitTypical SizesNotes
Water Services & LoopsPVC C900, HDPE SDR, Copper (service)¾"–8"+Tracer wire as required; thrust blocks at fittings by spec
Sewer LateralsPVC SDR 35/26 (by jurisdiction)4"–8"+Grade/flow per design; verify tie-in elevations
Force MainsHDPE SDR, PVC C9002"–12"+Pressure test by spec; air release appurtenances by design
Casing (if required)Steel or HDPE casingAs specifiedCarrier pipe spacers; end seals and annular fill per plans

We provide pull strings, labeling, and documentation; pressure/mandrel tests coordinated with your plumber or inspector.

Safety & Permits

Our workflow includes 811 tickets, potholing, and traffic control where required. We maintain utility separations per code and coordinate inspections to keep the project moving.

  • Call 811 before any digging activity
  • OSHA safety standards observed on site
  • ODOT permits and ROW coordination
Directional boring with water line pullback

Directional Boring vs. Open-Cut Trenching

Directional Boring (HDD)

  • Minimal disturbance with small entry/exit pits
  • Faster restoration and less traffic control
  • Cross roads, drives, trees, and creeks cleanly
  • Accurate separations from other utilities
  • Lower total cost in sensitive or finished areas

Open-Cut Trenching

  • Long surface cuts and heavy restoration
  • More lane closures and public disruption
  • Higher risk to trees/landscaping and hardscapes
  • Difficult around dense utility corridors
  • May be cheaper only in rough, unpaved areas
Water service bore beneath a driveway
HDPE water line pullback through reamed bore
Ready to Build

Let’s Plan Your Water or Sewer Route

Share your alignment, pipe sizes, and schedule—we’ll propose the fastest, cleanest solution.

Water & Sewer Directional Boring — FAQ

Do you handle residential service replacements?

Yes. We routinely bore new water services and sewer laterals under driveways and landscaping with minimal disturbance. We coordinate with your plumber for tie-ins and tests per local code.

How do you verify depth and avoid existing utilities?

We open an 811 ticket, verify marks, and pothole/daylight critical crossings to physically confirm line and depth. We steer pilot bores to maintain proper cover and separations.

What pipe types do you install?

Water: PVC C900, HDPE SDR, copper (services). Sewer: PVC SDR 35/26 (by jurisdiction). Force mains: HDPE/PVC by spec. We can also install carrier pipe in casing where required.

Can you provide documentation for inspectors?

Yes. We provide photos, bore logs, and as-built information as requested. Pressure or mandrel tests are coordinated with your plumber or specified subcontractor.

How soon can you mobilize?

Mobilization depends on locates, permits, and material availability. Send your scope and we’ll give you the fastest realistic start date.

Skip to content
Get a Fast HDD Quote

Water & Sewer Directional Drilling

Potable Water, Force Mains & Sewer Laterals — HDD Done Right

Inspector-ready trenchless installs for municipalities, contractors, campuses, and property owners. Serving all of Oklahoma and surrounding states.

Trinity Boring Solutions • 9201 NW Expressway, Yukon, OK 73099

  • HDD / Trenchless
  • 811 Safe
  • OSHA Compliant
  • Hydro‑Vac Daylighting
  • As‑Built & Testing
Water & Sewer HDD: low‑impact trenchless installs, inspector‑ready paperwork. Call Now Request Quote
Municipality Placeholder Utility Owner Placeholder GC Placeholder Engineering Placeholder Campus Placeholder Developer Placeholder

Directional Drilling for Water & Sewer Utilities

We install potable water lines, force main sewer, and service laterals with clean HDD methods. Our crews daylight conflicts with hydro‑vac, steer pilots with telemetry, and ream to the right sequence so product pipe pulls clean and passes testing. We plan for depth, separation, bend radii, and grade; deliver as‑built summaries; and support pressure/air tests and disinfection so closeout is quick.

Quick Cost Range Estimator (non‑binding)

Key Water & Sewer HDD Services

  • 💧

    Potable Water Services & Renewals

    Restrained joints, disinfection support, inspector‑ready documentation, neat entry/exit pits.

    Potable water service placeholder Request Quote
  • 🔁

    Force Main Sewer Bores

    Grade‑aware routing for lift‑station tie‑ins and long crossings beneath roads/rails/drainage.

    Force main placeholder Request Quote
  • 🛣️

    Main Extensions & Crossings

    Under streets and sidewalks with small access windows and minimal restoration footprint.

    Crossing placeholder Request Quote

Before / After: Why Trenchless Wins

Open cut
HDD trenchless

Our Trenchless Process

  1. 1Pre‑Plan & Ticketing811 locates, drawings review, method statement, JHA, MOT if needed.
  2. 2Hydro‑Vac DaylightingVerify depth/offset at conflicts, log photos and notes.
  3. 3Pilot BoreTelemetry steering; grade, separation, and entry/exit geometry controlled.
  4. 4Ream & ConditionSequenced reamers matched to soils and diameter; hole stability preserved.
  5. 5Product PullHDPE/C900/DIP‑in‑casing per plan; restraints and fittings to spec.
  6. 6Test & TurnoverPressure/air tests, disinfection support, as‑builts, tidy restoration.

How We Daylight Safely (Hydro‑Vac)

  1. Mark suspected conflict zones and set up traffic/pedestrian control.
  2. Hydro‑vac to target depth; verify separation with calibrated probe.
  3. Log photos, depth/offset, and soil notes; update bore plan.
  4. Protect exposure with plates/cones; restore area after pullback.

Specifications & Capabilities

  • HDPE (DR/SDR per spec), C900 PVC, restrained‑joint PVC, DIP in casing;
  • Approved fittings, restraint systems, thrust blocks where required;
  • Tracer wire/conduit as specified; disinfectant protocol for potable work.
Typical Bore Diameters1” – 16”+ (larger by scope)
Typical LengthsShort services to long crossings under road/creek/rail
Depth / GradePer plan and jurisdiction; gravity/grade‑sensitive entries/exits
LocatingWalk‑over telemetry (depth, roll, pitch) + as‑built alignment summaries
HDD rig
Rig classes sized to crossing geometry and soil profile.
Reamers
Reamer sets matched to diameter targets; cleaning passes as needed.
Hydro‑vac
Hydro‑vac daylighting at all conflicts for safe verification.
  • Hydro‑vac photos at conflicts; depth/offset notes logged;
  • Pressure and air tests; disinfection for potable lines;
  • As‑built summary and photo packet for closeout.
  • Small access windows; sod plugs or asphalt cores/patches to spec;
  • Sidewalk/drive replacements coordinated with owners/AHJ;
  • Tidy staging/cleanup to protect public access and curb appeal.

Field Operations

Visit or Request a Site Walk

Open in Maps

Safety & Compliance

  • 811 Locates
  • OSHA Protocols
  • EPA Potable Handling
  • Traffic Control/MOT
  • Daily JHAs
  • Mandatory potholing at all conflicts; photo documentation
  • Competent person oversight, stop‑work authority
  • Pedestrian protection and site signage in occupied areas
  • Disinfection, pressure/air test coordination and records

Frequently Asked Questions

Can you hold grade for sewer or precise elevations for water tie‑ins?
Yes. We pre‑survey entry/exit, plan bend radii, and steer with telemetry to hit design elevation. For gravity, we coordinate grade checks at tie‑in.
How do you handle disinfection and testing on potable lines?
We support chlorination, swabbing, pressure/air testing, and recordkeeping per AHJ. Documentation is packaged with as‑built summaries for closeout.
What if there are unknown utilities?
We daylight conservatively at suspected conflicts, adjust the bore path, and maintain jurisdictional separations. Safety and documentation come first.
Do you work in hospitals, schools, or neighborhoods without disruption?
Yes. HDD is ideal in sensitive corridors. We implement pedestrian protection, schedule off‑peak, and keep sites tidy.

Request a Water & Sewer HDD Quote

Send your plan or sketch. We’ll mark daylight points, define a trenchless sequence, and return a clear proposal with schedule options.